Add to Cart
Product features:
1. Contains four functions of mains bypass, mains charging, inverter, UPS, fully automatic switching
2. The efficiency is 3~5% higher than the ordinary power frequency series, and the self-consumption is reduced by 30~50%
3. Three-in-one function, inverter & control & lithium battery integrated cabinet
4. DIP switch selection: battery undervoltage point, input AC range, energy saving mode, priority mode
5. Remote Communication Interface RJ11 / RJ45 / RS232 / 485 App Monitoring Remote Control Panel (optional)
6. Pure sine wave output, input and output is completely isolated
7. Contains the four-stage charging mode, the charging current is automatically adjusted
8. Mixed power supply such as the power generation of the main electricity, built-in solar MPPT controller
9. Tolerate 3 times rated power start, carry capacity excellence
10.LED Display working conditions, LCD remote display running parameters
11. undervoltage / overvoltage / short circuit / overload / over temperature protection
12. Pure sine wave series inverter is suitable for renewable energy systems, utilities, Route,oceanand emergency application.
HR series parameter table
NO | MODEL | ESS-HR3048 | ESS-HR5048 | ESS-HR6048 | ESS-HR8048 | ESS-HR10048 | ESS-HR12048 | |||||
1 | battery voltage | 51 .2Vdc | ||||||||||
2 | battery capacity | 2OOAH | 2OOAH | 3OOAH | 4OOAH | 5OOAH | 6OOAH | |||||
3 | battery power | 1 0.24 KWH | 1 O.24KWH | 1 5.36 KWH | 2O.48KWH | 25.6KWH | 3O.72KWH | |||||
4 | Battery configuration | 48V200AH *1PCS | 48V200AH*1PCS | 48V15OAH *2PCS | 48V200AH*2PCS | 48V175AH*3 PCS | 48V200AH*3 PCS | |||||
5 | Numberof batteries | 48V20OAH 1PCS | 48V200AH 1PCS | 48V15OAH 2PCS | 48V200AH 2PCS | 48V175AH 3PCS | 48V200AH 3PCS | |||||
6 | Rated charging voltage | 56.Ovdc | ||||||||||
7 | Maximum charging voltage | 58.4vdc | ||||||||||
8 | Overcharge protection | 58.4vdc | ||||||||||
9 | Rated charging current | 5OA | 5OA | 60A | 8OA | 10OA | 12OA | |||||
1O | Maximum charging current | 8OA | 80A | 10OA | 12OA | 15OA | 20OA | |||||
11 | Overcharge protection | Reboot | ||||||||||
12 | Charging temperature | 0~45℃ | ||||||||||
13 | Output voltage range | 4O-56Vdc < 46Vdc or 48Vdc inverter cut off by SW1 setting > | ||||||||||
14 | Nozzle discharge current | 12OA | 12OA | 24OA | 240A | 36OA | 36OA | |||||
15 | Maximum discharge current | 24OA | 24OA | 30OA | 40OA | 50OA | 60OA | |||||
16 | Overcharge protection | Reboot | ||||||||||
17 | Discharge temperature | 0~45℃ | ||||||||||
18 | Communication Interface | RS485 for LCD/CAN Computer monitoring | ||||||||||
Inverter <built-in) | HR3O48 | HR5O48 | HR6O48 | HR8O48 | HR10O48 | HR12048 | ||||||
1 | rated power | 3KW | 5KW | 6KW | 8KW | 10KW | 12KW | |||||
2 | Output voltage waveform | Pure sine wave (mains or generator) | ||||||||||
3 | Rated efficiency | >88% (peak) inverter mode />95% line mode | ||||||||||
4 | Power factor | 0.9-1.0 | ||||||||||
5 | Rated output voltage | 220Vac or 230Vdc or 240Vac or 110Vac or 120Vac (L-N) &240Vac ( H-H)120Vac ( H-N)±10%RMS | ||||||||||
6 | Output frequency | 50 or 60±0.3HZ (inverter mode set by sw4)) | ||||||||||
7 | Typical switching time | 4-6 seconds typical, 10 seconds (maximum) | ||||||||||
8 | Total harmonic distortion | <3%<rated voltage) | ||||||||||
9 | AC input range | 184-253Vac (UPS mode) or 140-270Vac (Generator mode) /96-135 (UPS mode) or 80-135Vac (Generator mode) | ||||||||||
1O | Custom AC charger | Battery type selector posial9, LEP special design, maximize battery cycle life | ||||||||||
11 | Maximum AC current | 60A | 60A | 8OA | 1OOA | 12OA | 12OA | |||||
12 | Battery priority function | Set by SW5 at position 1 <inverter mode valid)-, AC automatic input battery voltage is lower than 48Vdc or 50Vdc | ||||||||||
13 | No charge for AC bypass | Battery type selector position 0 | ||||||||||
MPPT (built-in) | 60A | 100A | 6OA*2 | 8OA*2 | 100A*2 | 80*3 | ||||||
1 | PV | 3400W | 5600W | 34OOW*2 | 454Ow*2 | 56OOW*3 | 4540w*3 | |||||
2 | Photovoltaic Discovery Group | 1 | 1 | 2 | 2 | 3 | 3 | |||||
3 | PV input range | 65-15OVdc | ||||||||||
4 | MPPT charging voltage | 56.4V (fast charge) / 54V (fast charge) | ||||||||||
Mechanical parameters | ESS-HR3048 | ESS-HR8048 | ESS-HR6048 | ESS-HR8048 | ESS-HR10048 | ESS-HR12048 | ||||||
1 | size(H*W*D>) | 800*600* 600mm | 1000*600* 600mm | 1000*600* 600mm | 1200*600* 600mm | 1200*600* 600mm | 1300*600* 600mm |
If the product model specification changes without notice