Add to Cart
PRODUCT DESCRIPTION:
HET HV solar off-grid vertical inverter series products areBuilt-in solar MPPT/PWM controller (optional), and complementary with mains Inverter control all-in-one machine, users only need external solar modules and batteries,It can form an off-grid power generation system;The user can set the sleep mode according to the actual situation, The solar energy priority mode is a multi-functional and intelligent inverter control all-in-one machine.
PRODUCT FEATURES:
1. Pure sine output is suitable for various loads. It can be used with mixed power supply such as mains/diesel generators Automatic switching of
2. 5 functions: mains bypass, mains charging, solar charging, inverter, UPS
3. Built-in MPPT/solar charge controller (controller power 40/60A/80A/120A optional)
4. Contains relay switching and AC/DC circuit breaker, with multiple protections such as undervoltage /overvoltage/short circuit/overload/over temperature
5. DIP switch selection: battery undervoltage point, input AC range, energy saving mode, output frequency, priority mode
6. The efficiency is 3~5% higher than the ordinary power frequency series, and the self-consumption is reduced by 30%~50%
7. Professional off-grid solar system solutions (optional)
8. Remote control RJ11/RJ45 and RS232/485 interface remote control panel (optional)
9. Pure sine wave series inverters are suitable for renewable energy systems, solar photovoltaic systems, vehicles, ships,Marine and emergency applications.



HV-pv Series parameter table
| Electrical Specifications | ||||||||||
| Model HV-PV | 1.0KW | 2.0KW | 3.0KW | 4.0KW | 5.0KW | 6.0KW | 8.0KW | 10.0KW | 12.0KW | |
|
Inverter output | rated power | 1.0KW | 2.0KW | 3.0KW | 4.0KW | 5.0KW | 6.0KW | 8.0KW | 10.0KW | 12.0KW |
| Peak power (2 seconds) | 3.0KW | 6.0KW | 9.0KW | 12.0KW | 15.0KW | 18.0KW | 24.0KW | 30.0KW | 36.0KW | |
| Output voltage waveform | Pure sine wave (mains or generator) | |||||||||
| Rated efficiency | >88%(Peak) | |||||||||
| Online mode efficiency | >95% | |||||||||
| Power factor | 0.9-1.0 | |||||||||
| Rated output voltage | 100-110-120Vac / 220-230-240Vac | |||||||||
| Output frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | |||||||||
| Short circuit | Yes, protection after 1 second short circuit | |||||||||
| protection | ||||||||||
| Typical switching time | 10ms (maximum) | |||||||||
| Total harmonic distortion | < 10% | |||||||||
|
DC input | Rated input voltage | 12.0Vdc / 24.0Vdc / 48.0Vdc | 24.0Vdc / 48.0Vdc | 48.0Vdc/60.0Vdc/72.0Vdc | ||||||
| Minimum starting voltage | 10.0Vdc / 10.5Vdc for 12Vdc Mode |
*2 for 24Vdc,*4 for 48Vdc*5 60VdcVdc *6 72Vdc | ||||||||
| Low battery voltage alarm | 10.5Vdc / 11.0Vdc for 12Vdc Mode | |||||||||
| Low voltage cut out | 10.0Vdc / 10.5Vdc for 12Vdc Mode | |||||||||
| High voltage cutting | 16.0Vdc for 12Vdc Mode | |||||||||
| Low voltage recovery | 15.5Vdc for 12Vdc Mode | |||||||||
|
Charge controll er | The output voltage | Depends on battery type | ||||||||
| Charging circuit breaker specifications |
15A |
20A |
30A |
40A |
40A |
40A |
50A |
80A |
80A | |
| Maximum charging current | See detailed table | |||||||||
| Starting voltage | 10.5-15.7Vdc for 12Vdc Mode |
*2 for 24Vdc, *4 for 48Vdc;*6 72Vdc | ||||||||
| Overcharge protection shutdown point | more than the 15.8Vdc for 12Vdc Mode | |||||||||
|
protect | Rated input voltage | 100-110-120Vac / 220-230-240Vac | ||||||||
| Maximum input voltage | 150VAC For 120Vac LV Mode ;300VAC For 230Vac HV Mode; | |||||||||
| Rated input frequency | 50Hz or 60Hz | |||||||||
| Low frequency cut out | 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | |||||||||
| High frequency cut out | 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | |||||||||
| Overload | yes | |||||||||
| protection | ||||||||||
| Output short circuit protection | yes | |||||||||
| Maximum bypass current | 30Amp | 40Amp | 80Amp | |||||||
|
Solar Control ler parame ter | Solar system voltage | MPPT12V/24V/36V/48V automatic recognition | ||||||||
| Open circuit voltage of photovoltaic panel | 18~150Vdc@ 12V 35~150Vdc@24V 60~150Vdc@48V | |||||||||
| Rated charging current | 30A-120A (optional) | |||||||||
| Charging efficiency | 97.6% | |||||||||
| Rechargeable battery type | Valve-regulated lead-acid battery Gel battery Lithium battery | |||||||||
| charging method | Four-stage charging: constant current charge, constant voltage charge, float charge, equal charge | |||||||||
| safety protection | Solar panel short circuit protection, overcharge protection, over discharge protection, overload protection | |||||||||
|
Mecha nical parame ters | Install | Wall mount | ||||||||
| Inverter size (length * width * height) | 380*215* 360mm |
490*215*410mm |
490*215*410mm |
480*300*715mm | ||||||
| Inverter shell size (length * width * height) |
— |
— |
— |
550*320*820mm | ||||||
| Net weight of inverter with solar rear KG |
— |
— |
— |
— |
— |
— |
63 |
65.5 |
66.5 | |
| Package includes solar rear unit net weight KG |
— |
— |
— |
— |
— |
— |
71.5 |
74 |
75 | |
| show | Status LEDs / Status LEDs+LCD | |||||||||
| Standard warranty | 2 year | |||||||||